Sensors & Probes
Ozone probe
Ozone or trace detection probe
SYCLOPE offers two types of ozone probe for the measurement of Ozone (O3) in water :
- CAA2550 : for a measurement from 0.02 to 2 ppm of ozone
- CAA2450: for the measurement of ozone traces over an extended period of time
What are the advantages of the ozone probe?
The PLUS for your use
Wintering & Return to service
To help you during the wintering and the restarting of your probes, you can download the following infographics…
Ozone sensor and Ozone Trace Detection Probe
Applications
- Drinking water
- Swimming pools
- Waters of similar quality
Measure
- Ozone
References
- CAA2550 : Ozone measurement
- CAA2450 : Ozone detection
Measuring range
- 0,02 – 2 ppm
pH range
- Ozone stability range
Temperature range
- 5 – 40°C (with temperature compensation)
Key Interference
- CAA2550 : Surfactants
- CAA2450 : Chlorine Dioxide, APA, Bromine
Maximum pressure and flow rate
- 1 bar
- Mini : 20 l/h
- Maxi : 100 l/h
- Recommended : 30 l/h
Start-up time and final calibration
- First calibration after 2 to 6 hours
- After 24 hours
Membrane lifetime
Depending on water quality :
- CAA2550 : Normally 1 year
- CAA2450 : Approximately 6 months
Electrolyte and Membrane
- CAA2550 :
Electrolyte : CAA2551 / Membrane : CAA2539 - CAA2450
Electrolyte : CAA2459 / Membrane : CAA2457
Material and type of protection
- CAA2550 : PVC black
CAA2450 : PVC C - IP 65
Power supply and output signal
- 16 – 24 VDC
- 4-20 mA