Conductive conductivity sensors

[vc_single_image image=”1602″ img_size=”full” alignment=”center”]

Graphite conductive conductivity sensors : CAA2640 to CAA2643
Graphite conductive conductivity sensors : CAA2648 – 49 and CAA2680 – 81
4-20 mA output

CAA2640 – 43 and CAA2648 – 49 sensors are used to measure conductivity with “graphite” electrode. These sensors are not suitable for low-mineralized water.
CAA2648 – 49 sensors provide a 4-20 mA analog signal for connection over long distances. A temperature sensor is integrated to enable the transmission of a compensated signal based on water temperature.

Advantages:

  • Continuous accurate and reliable analysis
  • Fast execution
[vc_empty_space height=”20px”]

Applications

[vc_empty_space height=”15px”][dt_vc_list bullet_position=”middle” dividers=”false”]
  • Cooling tower
  • Drinking water
  • Brackish water
[/dt_vc_list]
[vc_empty_space height=”40px”][dt_vc_list bullet_position=”middle” dividers=”false”]
  • Waste water
  • Swimming pools
[/dt_vc_list]
[vc_empty_space height=”40px”][dt_vc_list bullet_position=”middle” dividers=”false”]
  • Seawater
  • Salinity measurement
[/dt_vc_list]
[vc_tta_tabs][vc_tta_section title=”Technical features” tab_id=”caracteristiques-techniques57a3-e868″]
Measure
  • Conductivity
Measurement range
  • 1 µS/cm – 20 mS/cm (CAA2640)
  • 0,01 – 20 mS/cm (CAA2643)
  • 0 – 2000 µS (CAA2648)
  • 0 – 100 mS (CAA2649)
Connection
  • 1/2” Gaz Male (CAA2640)
  • PG13,5 Male (CAA2643)
  • 1” Gaz Male (CAA2648 – 49)
Connector
  • Without
Nature of electrodes
  • Graphite
Body nature
  • PVC (CAA2640)
  • Epoxy (CAA2643)
  • PVC + head PVDF (CAA2648 – 49)
Applications
  • Cooling tower, waste water, seawater (CAA2640)
  • Cooling tower, waste water, drinking water (CAA2643)
  • Cooling tower, swimming pools (CAA2648)
  • Seawater, brackish water, salinity measurement (CAA2649)
Maximum pressure
  • 5 bars (at 25°C) (CAA2640)
  • 16 bars (CAA2643)
  • 6 bars (at 25°C) (CAA2648 – 49)
Temperature range
  • 0 – 45°C (CAA2640)
  • 0 – 80°C (CAA2643)
  • -20 – 120°C (CAA2648 – 49)
Lifetime
  • 3 to 5 years in normal use (CAA2640 – 43)
Features
  • CAA2643 contains an integrated PT100 temperature sensor to perform a compensation of the conductivity measurement
  • CAA2648 – 49 : T°C compensation = 2%/°C
Output signal
and power supply
  • 4-20 mA – 8,5 at 36 VDC (CAA2648 – 49)
[/vc_tta_section][vc_tta_section title=”Example of installation” tab_id=”installation-type57a3-e868″]

For more information

[vc_empty_space height=”20px”][vc_btn title=”Contact us” style=”custom” custom_background=”#0079ac” custom_text=”#ffffff” shape=”square” size=”sm” link=”url:mailto%3Asyclope%40syclope.fr|title:Nous%20consulter||rel:nofollow”][/vc_tta_section][vc_tta_section title=”Download” tab_id=”telechargements57a3-e868″ el_class=”tab3″]

For more information

[vc_empty_space height=”20px”][vc_btn title=”Contact us” style=”custom” custom_background=”#0079ac” custom_text=”#ffffff” shape=”square” size=”sm” link=”url:mailto%3Asyclope%40syclope.fr|title:Nous%20consulter||rel:nofollow”]
[/vc_tta_section][/vc_tta_tabs]

Price request