Hit enter to search or ESC to close
Syclope Electronique
  • Home
  • Applications
    • Swimming Pools
      • Public swimming pools – Aquatic centers
      • Hotels – Campsites – Spas
      • Thermal waters – Thalassotherapy
      • Private pool
      • Aquatic zoo
    • Drinking Water & Process Water
      • Sanitary hot water
      • Cooling tower
      • Drinking water
      • Process water
      • Breeding
      • Consumption of water on airplane
  • SYCLOPE products
    • Analysis & Control of water
      • ALTICEO
      • ODITouch
      • TEREO Touch XL
      • INDIGO
      • HYDRO Touch
      • UNISEAU
      • DOUBLEAU
      • COOLPAC
      • TRACEO
      • ECS Pro Panel
    • Probes & Sensors
      • Chlorine probe
      • Temperature
      • pH
      • Redox ORP
      • Bromine
      • Copper platinum
      • Ozone
      • Conductivity
      • Turbidity
      • Peracetic acid
      • Hydrogen peroxide
      • Chlorine dioxide
      • Dissolved oxygen
      • Chlorites
    • Measuring cell
      • Piping cell
      • PMMA Transparent cell
      • Copper platinum cell
    • Trichloramine & Photometers
      • Tricklorame V2
      • TRIKLO’Live – continuous measurement
      • Photometers
      • Photometer Lilian
    • Dosing & Storage
      • Dosing pumps
      • Product tank
      • Chlorine gas
    • Salt chlorinator
    • Ultrafiltration – UFPOOL
    • Water purification unit
    • Communication
      • Maintenance software
      • MYSCLOPE.COM
      • HYDRO’Com
      • MyHydro Connect
  • Company
    • Who are we?
    • Jobs
  • Contact
  • SYCLOPE Advice
    • Public Pool Regulations
    • Chloramines
    • Taylor Balance
    • Active chlorine
    • ph redox sensors
    • Manuals
    • Videos
    • Catalogue
  • French

Free Chlorine sensors

[vc_single_image image=”6808″ img_size=”full” alignment=”center”]

Free Chlorine sensors : CAA2920
4-20 mA / 0 … 10 ppm

CAA2920 sensors are used to measure free chlorine (HOCl and OCl) and organically bound chlorine in swimming pool water or similar water quality. Thanks to its gold working electrode, this sensor is able to measure free chlorine generated with in-line electrolysis system.

Advantages:

  • Amperometric measurement
  • Continuous accurate and reliable analysis
  • Fast execution
[vc_empty_space height=”20px”]

Applications

[vc_empty_space height=”15px”][dt_vc_list bullet_position=”middle” dividers=”false”]
  • Swimming pools
[/dt_vc_list]
[vc_empty_space height=”40px”][dt_vc_list bullet_position=”middle” dividers=”false”]
  • Water of similar quality (free of surfactants)
[/dt_vc_list]
[vc_tta_tabs][vc_tta_section title=”Technical Features” tab_id=”caracteristiques-techniques7536-86c3″]
Measure
  • Free chlorine
Measurement range
  • 0,1 – 10 ppm
pH range
  • 5,5 – 9,5 pH
Temperature range
  • 5 – 45°C (with temperature compensated)
Sensitivity to cyanuric acid
  • No sensitivity if > 5mg/l of cyanuric acid
Maximum pressure and
supply flow
  • 3 bars
  • Mini: 20 l/h
  • Maxi: 100 l/h
  • Recommanded: 30 l/h
Starting time and
definitive calibration
  • First calibration after 2 h
  • After 24 h
Membrane cap lifetime 
  • Currently 1 year (according to water quality)
Membrane and Electrolyte
  • Membrane: CAA2509
  • Electrolyte: CAA2511
Material and
protection type
  • Black PVC
  • IP 65
Supply voltage and
output signal
  • 16 – 24 VDC
  • 4-20 mA
[/vc_tta_section][vc_tta_section title=”Example of Installation” tab_id=”installation-type7536-86c3″]

For more information

[vc_empty_space height=”20px”][vc_btn title=”Contact us” style=”custom” custom_background=”#0079ca” custom_text=”#ffffff” shape=”square” size=”sm” align=”left” link=”url:mailto%3Asyclope%40syclope.fr|title:Nous%20consulter|target:%20_blank|rel:nofollow”][/vc_tta_section][vc_tta_section title=”Download” tab_id=”telechargements7536-86c3″ el_class=”tab3″]

Technical manual

Free chlorine – CAA2920

[/vc_tta_section][/vc_tta_tabs]

Price request


    Secteurs d’Activités

    • Swimming pools
    • Drinking Water & Industrial Water

    Produits

    • Analysis & Control of water
    • Probes & Sensors
    • Measuring cell
    • Trichloramine & Photometers
    • Dosing & Storage
    • Ultrafiltration – UFPOOL
    • Communication

    Société

    • Jobs
    • Who are we ?
    • France & Worldwide
    • Jobs

    Syclope Electronique

    Rue de Bruscos
    64230 SAUVAGNON
    Tél : +33(0)5 59 33 70 36
    Fax : +33(0)5 59 33 70 37
    Email : syclope@syclope.fr
    Siret : 383 612 009 00035
    TVA intracommunautaire :
    FR 06 383612009

    ©2020 SYCLOPE Electronique - Tous droits réservés | Informations légales | Politique de confidentialité | CGV

    • Home
    • Applications
      • Swimming Pools
        • Public swimming pools – Aquatic centers
        • Hotels – Campsites – Spas
        • Thermal waters – Thalassotherapy
        • Private pool
        • Aquatic zoo
      • Drinking Water & Process Water
        • Sanitary hot water
        • Cooling tower
        • Drinking water
        • Process water
        • Breeding
        • Consumption of water on airplane
    • SYCLOPE products
      • Analysis & Control of water
        • ALTICEO
        • ODITouch
        • TEREO Touch XL
        • INDIGO
        • HYDRO Touch
        • UNISEAU
        • DOUBLEAU
        • COOLPAC
        • TRACEO
        • ECS Pro Panel
      • Probes & Sensors
        • Chlorine probe
        • Temperature
        • pH
        • Redox ORP
        • Bromine
        • Copper platinum
        • Ozone
        • Conductivity
        • Turbidity
        • Peracetic acid
        • Hydrogen peroxide
        • Chlorine dioxide
        • Dissolved oxygen
        • Chlorites
      • Measuring cell
        • Piping cell
        • PMMA Transparent cell
        • Copper platinum cell
      • Trichloramine & Photometers
        • Tricklorame V2
        • TRIKLO’Live – continuous measurement
        • Photometers
        • Photometer Lilian
      • Dosing & Storage
        • Dosing pumps
        • Product tank
        • Chlorine gas
      • Salt chlorinator
      • Ultrafiltration – UFPOOL
      • Water purification unit
      • Communication
        • Maintenance software
        • MYSCLOPE.COM
        • HYDRO’Com
        • MyHydro Connect
    • Company
      • Who are we?
      • Jobs
    • Contact
    • SYCLOPE Advice
      • Public Pool Regulations
      • Chloramines
      • Taylor Balance
      • Active chlorine
      • ph redox sensors
      • Manuals
      • Videos
      • Catalogue
    • French