CHLORINE SENSOR

FREE CHLORINE

ACTIVE CHLORINE

TOTAL CHLORINE

FREE CHLORINE

Sondes de chlore CAA2920 : 4-20 mA / 0 ... 10 ppm

SYCLOPE offers a wide range of free chlorine probes for measurement in swimming pool water or water of similar quality.

Standard free chlorine sensors CAA2505 – CAA2506

The amperometric measuring probes type CAA2505 and CAA2506 are used to measure free, organically bound chlorine, i.e. chlorine combined with isocyanuric acid, in swimming pool water or water of similar quality.

Special free chlorine measurement for combined chlorine CAA2305 – CAA2306

These amperometric sensors are used to measure free organically bound chlorine. This is chlorine combined with isocyanuric acid in swimming pool water or similar water. These sensors are equipped with a gold head electrode.

What are the advantages of these free chlorine sensors?

  • Precise continuous analysis
  • Amperometric measurement
  • These free chlorine probes are insensitive to other water parameters (flow rate, pH, temperature, etc.).
FREE Chlorine Sensor Standard : CAA2505 – CAA2506 For combined chlorine: CAA2305 – CAA2306
Applications
  • Swimming pool water
  • Water of similar quality
Measure
  • Free Chlorine
Measuring range
  • 0,02 – 2 ppm (CAA2505)
  • 0,1 – 10 ppm (CAA2506)
  • 0,02 – 2 ppm (CAA2305)
  • 0,1 – 10 ppm (CAA2306)
pH range
  • 5,5 – 9,5 pH
Temperature
  • 5 – 45°C (with temperature compensation)
Sensitivity to cyanuric acid
  • No sensitivity
    if > 5mg/l cyanuric acid
Maximum pressure and flow rate
  • 0,5 bars
  • Mini : 20 l/h
  • Maxi : 100 l/h
  • Recommended : 30 l/h
Start-up time and
final calibration
  • First calibration after 2 h
  • After 24 hours
Membrane lifetime
  • Normally 1 year
    (depending on water quality)
Membrane and Electrolyte
  • Membrane : CAA2509
  • Electrolyte : CAA2511
Material and type of protection
  • PVC black
  • IP 65
Power supply and output signal
  • 16 – 24 VDC
  • 4-20 mA

ACTIVE CHLORINE

Sondes de chlore CAA2920 : 4-20 mA / 0 ... 10 ppm

In addition to the free chlorine range, SYCLOPE also offers a wide range of active chlorine probes for water treatment.

CAA2507 : sonde de mesure de chloreStandard active chlorine sensors CAA2527, CAA2507

The standard amperometric measuring probes allow the measurement of active chlorine, i.e. hypochlorous acid in drinking water, swimming pool water (without chlorine stabilizer), seawater or water of similar quality.

CAA2507 : sonde de mesure de chloreActive chlorine sensors for process water CAA2557, CAA2545

These active chlorine sensors are especially used for the analysis of process water (without surfactants). These sensors can measure a high chlorine content of up to 200 mg/l chlorine.

sonde de chlore actif

Special active chlorine measurement for hot water CAA2563, CAA2569

These amperometric sensors are used to measure the hypochlorous acid present in hot water systems and are specially adapted for measurements under pressure (up to 8 bars). These probes are generally used for monitoring chlorination against legionella.

sonde de chlore syclopeSpecial active chlorine sensors for polluted water CAA2542

These probes are used to measure active chlorine in polluted water or for water containing surfactants or surfactants. These sensors are equipped with a special silicone membrane.

What are the advantages of these active chlorine sensors?

  • Accurate continuous analysis
  • Amperometric measurement
  • Wide range according to applications
ACTIVE chlorine sensors Standard : CAA2527, CAA2507 For domestic hot water :
CAA2563 and CAA2569
For process water :
CAA2542, CAA2557 & CAA2545 
Applications
  • Drinking water
  • Swimming pool water
  • Water of similar quality
  • Domestic hot water
  • Process water
  • Wastewater (CAA2542)
  • Polluted waters (CAA2542)
Measure
  • Active chlorine (hypochlorous acid) HOCl
  • Eau de process
  • Eaux chargées (CAA2542)
  • Eaux polluées (CAA2542)
Measuring range
  • 0,02 – 2 ppm (CAA2527)
  • 0,1 – 10 ppm (CAA2507)
  • 0 – 2 ppm (CAA2563)
  • 0 – 10 ppm (CAA2569)
  • 0,5 – 100 ppm (CAA2642)
  • 0,5 – 200 ppm (CAA2542)
  • 0,5 – 100 ppm (CAA2557)
  • 0,5 – 200 ppm (CAA2545)
pH range
  • 5,5 – 8 pH
  • 5 – 9 pH
  • 5,5 – 8 pH
Temperature range
(with temperature compensation)
  • 5 – 50°C
  • 40 – 50°C
  • 5 – 50°C
Disturbance by other oxidants
  • Free of cyanuric acid
  • Chlorine dioxide (4x)
  • Chlorites
  • Ozone (9x)
  • Free of cyanuric acid
Maximum pressure
and flow rate
  • 3 bars
  • Mini : 20 l/h
  • Maxi : 100 l/h
  • Recommended : 30 l/h
  • 8 bars
  • Mini : 20 l/h
  • Maxi : 80 l/h
  • Recommended : 30 l/h
  • 1 bar
  • Mini : 20 l/h
  • Maxi : 100 l/h
  • Recommended : 30 l/h
Start-up time and
final calibration
  • First calibration after 2 h
  • After 24 hours
Membrane lifetime
  • Normally 1 year (depending on water quality)
Membrane and Electrolyte
  • Membrane : CAA2539
  • Electrolyte : CAA2523
  • Without
  • CAA2542
    Membrane : CAA2543
    Electrolyte : CAA2544
  • CAA2557, CAA2545
    Membrane : CAA2539
    Electrolyte : CAA2523
Material and type of protection
  • PVC black
  • IP 65
  • PPE beige
  • IP 65
  • PVC black
  • IP 65
Power supply and output signal
  • 16 – 24 VDC
  • 4-20 mA
  • 10 – 25 VDC
  • 4-20 mA
  • 16 – 24 VDC
  • 4-20 mA

TOTAL CHLORINE

Sondes de chlore CAA2920 : 4-20 mA / 0 ... 10 ppm

SYCLOPE offers a range of total chlorine probes for water treatment.

Total Chlorine Sensors CAA2530 and CAA2531

Measuring cells type CAA2530 and CAA2531 are used to measure Total Chlorine, i.e. all bound chlorines, measured at DPD no. 4, in drinking water, sanitary water, process water or swimming pool water for the determination of combined chlorines (with free chlorine probe CAA2306).

What are the advantages of these total chlorine probes?

  • Accurate continuous analysis
  • Amperometric measurement
  • Wide range according to applications
TOTAL chlorine sensors  Standard : CAA2530 and CAA3531
Applications
  • Drinking water
  • Swimming pool water
  • Process water
  • Sanitary water
Measure
  • Total chlorine
Measuring range
  • 0,1 – 10 ppm (CAA2530)
  • 0,02 – 2 ppm (CAA2531)
pH range
  • 5,5 – 9,5 pH
Temperature range
(with temperature compensation)
  • 5 – 45°C
Maximum pressure and flow rate
  • 3 bars
  • Mini : 20 l/h
  • Maxi : 100 l/h
  • Recommended : 30 l/h
Start-up time and
final calibration
  • First calibration after 2 h
  • After 24 hours
Membrane lifetime
  • Normally 1 year (depending on water quality)
Membrane and Electrolyte
  • Membrane : CAA2509
  • Electrolyte : CAA2511
Material and type of protection
  • PVC black
  • IP 65
Power supply and output signal
  • 16 – 24 VDC
  • 4-20 mA